Fire-Resistant Duct Inspection Services

International Standards · Accredited Certification · Safety Assurance

Liansuo Construction Technology Co., Ltd. provides professional on-site inspection services for fire-resistant duct systems to ensure building ventilation systems maintain fire-resistance integrity under fire conditions, preventing the spread of flames and smoke to safeguard life safety and protect property. Services are conducted in accordance with ISO/IEC 17020 and recognized under IAS AC98 accreditation, with all inspectors authorized under international standards.

Reference Standards

  • ASTM E3385 – Standard Practice for On-site Inspection of Fire Resistive Duct Systems
  • UL 2221 – Standard for Tests of Fire Resistive Grease Duct Enclosure Assemblies
  • ASTM E2336 – Test Methods for Fire Resistive Grease Duct Enclosure Systems
  • ASTM E2816 – Test Methods for Fire Resistive Metallic HVAC Duct Systems
  • ISO 6944-1 – Fire Containment – Elements of Building Construction – Part 1: Ventilation Ducts

Scope of Inspection

  • Grease Duct Systems: Ensuring commercial kitchen exhaust ducts comply with fire-protection requirements
  • HVAC Air Duct Systems: Verifying ductwork integrity and installation quality across fire compartments
  • Hazardous Exhaust Systems: Specialized inspections for chemical, laboratory, and energy sector ventilation systems

Inspection Procedure

  • Preparation Stage
    • Review technical documents and listed product data
    • Verify materials and components (steel thickness, fireproof coatings, reinforcement, etc.)
    • Develop on-site inspection plan
  • Inspection Process & Key Focus Areas
    • Duct Construction: Materials, thickness, seams, and airflow requirements
    • Joints and Connections: Flange types, spacing, and assembly methods
    • Reinforcement: Dimensions and spacing of reinforcement rods
    • Fire Protection System: Fire rating, material thickness, and density compliance
    • Supports and Hangers: Type, spacing, and load-bearing capacity
    • Access Doors: Construction and fire-protection measures (if applicable)
  • Reporting & Re-Inspection
    • Documentation: Record all non-conformities in inspection checklist
    • Reporting: Issue inspection reports to contractors and clients
    • Corrective Action & Re-Inspection: Follow-up inspections to confirm compliance with design listings and standards

Deliverables

  • Work Instruction
  • Fire-Resistant Duct Inspection Checklist
  • Inspection Report

Key Advantages

  • International Recognition: Fully compliant with ISO/IEC 17020 and IAS AC98 accreditation requirements
  • Authoritative Oversight: Inspectors authorized under international standards.
  • Traceable Process: Comprehensive documentation through checklists, images, and reports
  • Risk Mitigation: Helping owners, contractors, and insurers identify and rectify potential hazards